Free cooling with air

Swapping your cooling tower for a dry liquid cooler or an adiabatic cooler is a great way to eradicate the risk of bacteria growing in your water. In fact, more countries are making the change to a more hygienic system a legal requirement every year.

When a dry liquid cooled condenser is far away from the chiller, a high level of glycol is added in the system for it to function correctly. To solve this, we can install an intermediate plate heat exchanger and minimize this circuit. So, you can save on glycol and unnecessary cost!


Find out more

Free cooling with air.jpg

.
AlfaLaval eBook Hero Banner Template 2024-12 A

Sustainable & Efficient Data Centers

Save up to 30% on cooling costs and boost revenue with liquid cooling—download our guide to learn how.

.
.

At Alfa Laval we're on a mission to help data centers

Data centers generate a lot of heat, but what if that heat could be put to good use? Heat recovery systems capture and repurpose excess energy, reducing CO2 emissions while cutting operational costs. Watch to learn how your data center can make a difference.

Cooling with heat exchanger

hvac_data_center_cooling_cooling_tower_chiller.jpg

When your dry liquid cooled condenser is far away from your chiller, extra glycol is used to make sure everything works correctly. The volume of glycol needed in this case is very high, and so is the cost. Installing a plate heat exchanger will substantially decrease the glycol circuit, reducing the volume and cost of your cooling system. On top of that, a plate heat exchanger will allow you to control the temperature of your protected loop to fit capacity and help avoid condensation on the outside piping.

Every loop in your system has a natural risk of condensation outside your media when the temperature contrast reaches it's dew point. This condensation can cause damage to the sensitive area inside your data center, so the more loops in your system, the more likely you are to have problems.

Cooling without heat exchanger

hvac_data_center_cooling_cooling_tower_chiller.jpg

Glycol is used in systems where the outside piping is at risk of ambient temperatures dropping below 0°C/32°F. That said, there are still many benefits to reducing your loop volume, even if freezing the cooling media is not a risk for your system.

Shield your data center with heat exchangers

There are many risks that come with using liquid in your cooling system. So, it’s important to protect the white space in the cooling loops from contamination and minimize the risk of leakages around electrical servers.

At Alfa Laval, we are constantly improving the design of our heat exchangers to help alleviate these challenges. To make that dream a reality, we have combined our world-leading expertise in data center cooling with proven heat exchanger solutions. This is guaranteed to increase reliability without compromising on the high efficiency levels you need.

Watch this video with our expert Cosimo Pecchioli to learn more about the challenges that come with using liquids in your cooling systems and how to solve them.

The benefits of a gasketed plate-and-frame heat exchanger

  • Volume isolation
  • Minimize the volume of glycol in your cooling circuit
  • Reduce the risk for condensation and damage inside your data center
  • Reduce the cost of cooling your production
  • Certified performance in accordance with AHRI regulations

 

Learn more about our gasketed heat exchangers

gphe_ahri_group-transparent.png

Savings across many dimensions

Using free cooling with water and a well-designed gasketed plate heat exchanger improves the cost-efficiency and sustainability of your data center in many ways. We know this because using AHRI performance certified heat exchangers has been proved to reduce your power usage effectiveness (PUE) by 2 %. It will even decrease the carbon usage effectiveness (CUE) of your facility by the same amount. Plus, a heat exchanger in your cooling system enables more efficient heat recovery and lower OPEX as a result. 


Contact us today to learn more

Discover the future of green IT with Alfa Laval

Alfa Laval has supplied solutions for dry liquid cooling systems since the earliest days of the internet. Today, we offer a wide range of solutions for data centers, all backed by a worldwide service network with experts who understand your business. By partnering with us as you begin planning your data center project, we can help you design a system that ensures you get maximum cooling efficiency and reliability.


See our total data center solutions

.
.
Request for service AlfaLaval Banner

Looking for service, support or repairs?

Our experts are available 24/7 and provide local repair service, parts, technical support and more!

.
.

Questions? Challenges? Support? Don’t worry – that’s what we’re here for.

Want to find out how the right cooling technology can help your data center achieve greener goals? Fill out the form, and one of our experts will get in touch with more information.

.
Accelerate Sustainable Solutions

Accelerating Sustainable

Heat exchangers that are changing energy efficiency in the petrochemicals industry.Accelerating Sustainable

.